Title
Efficient Method To Measure Imd Of Power Amplifier With Simplified Phase Determination Procedure To Clarify Memory Effect Origins
Abstract
This paper describes a time-domain expression based on the physical model of power amplifiers where electric memory effect is considered to be caused by even-order nonlinearity and bias impedance. It is demonstrated that the time-domain expression is consistent with the general memory polynomial reported by D.R. Morgan et al. To confirm validity of the physical model, a simple method is proposed to measure amplitude and phase of IMD by two tone test: the phase is extracted from measured small signal S-parameters of the amplifier under test. The method is applied to a GaN FET amplifier under condition that memory effect is enhanced by applying inductive cable for DC supply. Frequency dependent IMD is fitted by a parallel connection of L, C, and R: it has been confirmed that the frequency dependence of IMD is given by the bias impedance at even order harmonics of envelope frequency. The frequency dependence assures the validity of the physical model as well as the time-domain expression.
Year
DOI
Venue
2010
10.1587/transele.E93.C.991
IEICE TRANSACTIONS ON ELECTRONICS
Keywords
Field
DocType
power amplifier, IMD measurement, memory effect, bias impedance, even order nonlinearity
Direct-coupled amplifier,Electronic engineering,Engineering,Electrical engineering,Amplifier
Journal
Volume
Issue
ISSN
E93C
7
1745-1353