Title
Failure Analysis-assisted FMEA
Abstract
In this paper, ordinary FMEA (Failure Mode and Effects Analysis) was applied during the design phase of an electric motor control system for vehicle HVAC (Heating/Ventilation/Air Conditioning). The analysis of the field data from the second year forces to review FMEA. The corrective actions, planned on the basis of the sole failure mode, as usual in FMEA, proved to be inadequate and Failure Analysis was performed to understand the failure mechanism of the indicted component and integrate. New proper corrective actions were devised and successfully implemented.
Year
DOI
Venue
2006
10.1016/j.microrel.2006.07.072
Microelectronics Reliability
Keywords
Field
DocType
control system,failure analysis,air conditioning,failure mode and effect analysis,failure mode,electric motor
Failure mode and effects analysis,Air conditioning,Ventilation (architecture),HVAC,Failure reporting, analysis, and corrective action system,Motor controller,Control system,Engineering,Reliability engineering,Machine control
Journal
Volume
Issue
ISSN
46
9
0026-2714
Citations 
PageRank 
References 
7
0.77
0
Authors
5
Name
Order
Citations
PageRank
G. Cassanelli1213.85
G. Mura2398.68
F. Fantini33310.12
M. Vanzi48933.52
B. Plano5123.24