Abstract | ||
---|---|---|
This paper presents a fault detection method for open-circuit faults of a switching device in neutral-point-clamped inverter systems, which is based on the inherent characteristic of continuous pulsewidth modulation. The proposed method is achieved by measuring the pole voltage and its duration time. The pole voltage includes information of switching states in the inverter system but not affected ... |
Year | DOI | Venue |
---|---|---|
2009 | 10.1109/TIE.2009.2019775 | IEEE Transactions on Industrial Electronics |
Keywords | Field | DocType |
Fault detection,Pulse width modulation inverters,Circuit faults,Power system reliability,Voltage,Switches,Pulse inverters,Electrical fault detection,Fault tolerance,Topology | Stuck-at fault,Inverter,Control theory,Fault detection and isolation,Voltage,Control engineering,Modulation,Electronic engineering,Fault tolerance,Engineering,Fault indicator,Open-circuit voltage | Journal |
Volume | Issue | ISSN |
56 | 7 | 0278-0046 |
Citations | PageRank | References |
10 | 0.91 | 9 |
Authors | ||
3 |
Name | Order | Citations | PageRank |
---|---|---|---|
Tae-jin Kim | 1 | 111 | 21.38 |
Woo-Cheol Lee | 2 | 25 | 3.57 |
Dong-Seok Hyun | 3 | 90 | 31.41 |