Abstract | ||
---|---|---|
A recent upgrade of the primary standard for electric alternating power at the Physikalisch-Technische Bundesanstalt improved the measurements, indicating that standard uncertainties of the order of 1 muW/VA are attainable. Investigations done to ensure such low uncertainty figures are presented, and the evaluation of measurement uncertainties is discussed in detail |
Year | DOI | Venue |
---|---|---|
2007 | 10.1109/TIM.2007.890620 | IEEE Transactions on Instrumentation and Measurement |
Keywords | Field | DocType |
Power measurement,Sampling methods,Measurement standards,Discrete Fourier transforms,Measurement uncertainty,Frequency measurement,Analog-digital conversion,Signal synthesis,Standards publication,Voltage | Primary standard,Voltage,Measurement uncertainty,AC power,Upgrade,Electronic engineering,Signal synthesis,Mathematics,Analog to digital conversion | Journal |
Volume | Issue | ISSN |
56 | 2 | 0018-9456 |
Citations | PageRank | References |
2 | 0.43 | 3 |
Authors | ||
3 |
Name | Order | Citations | PageRank |
---|---|---|---|
Waldemar G. Kürten | 1 | 52 | 17.03 |
Enrico Mohns | 2 | 47 | 18.56 |
Kristian Dauke | 3 | 2 | 0.43 |