Title
Optimization of sustain pulse parameters for luminous efficacy improvement in an AC plasma display panel.
Abstract
In this paper, we report the experimental findings for improving the luminance and luminance efficacy in an AC plasma display panel using a new sustain waveform. The original waveform consists of bipolar sustain pulses of equal amplitudes and widths on both the sustain and scan electrodes. The proposed waveform modifies the pulse width and amplitude of the conventional bipolar voltage pulses. On reducing the pulse width of one of the applied sustains pulse; we observe the increase in luminance by 17% and luminance efficacy by 36% which is independent of the pulse polarity. The application of negative wider pulse (2.1μs) of high amplitude (180V) and positive shorter pulse (0.5μs) of low amplitude (30V) yields additive enhancement of the luminance by 26% and luminance efficacy by 19%. This new sustain waveform can be used to develop new generation high efficacy plasma displays.
Year
DOI
Venue
2010
10.1016/j.displa.2010.03.001
Displays
Keywords
Field
DocType
Plasma display panel,Luminance efficacy,Sustain waveform,PDP driving,Bipolar waveform
Plasma display,Waveform,Optics,Pulse-width modulation,Pulse (signal processing),Luminous efficacy,Pulse duration,Engineering,Luminance,Amplitude
Journal
Volume
Issue
ISSN
31
3
0141-9382
Citations 
PageRank 
References 
0
0.34
0
Authors
5
Name
Order
Citations
PageRank
Shashank Sharma1223.47
Abhishek Srivastava28822.03
Harmeet Singh3264.77
M. Raja400.34
H.K. Dwivedi500.34