Abstract | ||
---|---|---|
Orthopedic surgeons have identified a need for calibration artifacts (phantoms) to establish the traceability (to the SI unit of length) of measurements performed with Computer Assisted Orthopedic Surgery (CAOS) systems. These phantoms must be lightweight, easy to transport and simple to use. In collaboration with medical professionals, National Institute of Standards and Technology (NIST) researchers have developed a family of novel CAOS phantoms designed to meet the metrology needs of this critical segment of the US healthcare industry. The phantoms function as a surrogate hip joint and pelvis and can be measured with CAOS systems using the same technique employed to measure a patient's hip joint and pelvis for replacement surgery. The phantoms contain a mechanical ball joint, which functions as a substitute for a patient's hip joint and small holes, referred to as target holes, for receiving the measuring probe of CAOS systems. The location of the mechanical ball joint and the relative positions of the target holes are measured using the CAOS system and the results compared to the known values for these quantities. The results of this comparison are then used to verify the CAOS system performance specifications. In order to determine the known values for the critical dimensions of the phantom, the mechanical ball joint location and target hole positions are measured with a Coordinate Measuring Machine [1] (CMM), which is more accurate than CAOS Systems. This paper will report on the calibration of the NIST prototype phantom using a CMM and simulation tools at NIST. |
Year | DOI | Venue |
---|---|---|
2008 | 10.1145/1774674.1774722 | PerMIS |
Keywords | Field | DocType |
caos systems,orthopedic hip surgery,caos system performance specification,known value,target hole,phantom,calibration,caos system,mechanical ball joint,novel caos,<i>computer assisted surgery</i>,hip arthroplasty,surrogate hip joint,<i>computer assisted</i> orthopedic surgery,hip joint,joint location,orthopedic surgery,system performance,critical dimension | Computer science,Imaging phantom,Artificial intelligence,Computer-assisted surgery,Surgery,Coordinate-measuring machine,Computer vision,Simulation,Ball joint,Metrology,Computer-assisted orthopedic surgery,NIST,Calibration | Conference |
Citations | PageRank | References |
0 | 0.34 | 0 |
Authors | ||
4 |
Name | Order | Citations | PageRank |
---|---|---|---|
Daniel Sawyer | 1 | 0 | 0.34 |
Nick Dagalakis | 2 | 0 | 0.34 |
Craig Shakarji | 3 | 1 | 1.41 |
Yong Sik Kim | 4 | 0 | 0.34 |