Abstract | ||
---|---|---|
The Microwave Humidity Sounder (MWHS) is a five-channel microwave radiometer in the range of 150-191 GHz onboard FengYun 3 (FY-3). Before the launch of FY-3A, the intensive thermal vacuum (TVAC) tests for MWHS had been carried out in a 2-m TVAC chamber, and the basic parameters such as receiver nonlinearity were obtained. Four-year operation shows that the performance of FY-3A MWHS remains stabile... |
Year | DOI | Venue |
---|---|---|
2012 | 10.1109/TGRS.2012.2214391 | IEEE Transactions on Geoscience and Remote Sensing |
Keywords | Field | DocType |
Calibration,Temperature measurement,Brightness temperature,Satellites,Microwave radiometry,Instruments | Meteorology,Brightness temperature,Depth sounding,Atmospheric temperature,Remote sensing,Temperature measurement,Mathematics,Calibration,Radiance,Microwave radiometer,Microwave humidity sounder | Journal |
Volume | Issue | ISSN |
50 | 12 | 0196-2892 |
Citations | PageRank | References |
2 | 0.51 | 4 |
Authors | ||
4 |
Name | Order | Citations | PageRank |
---|---|---|---|
Songyan Gu | 1 | 3 | 1.57 |
Yang Guo | 2 | 2 | 1.86 |
Zhenzhan Wang | 3 | 31 | 15.91 |
Naimeng Lu | 4 | 2 | 0.85 |