Title
Analysis Of Over-Voltage Of Dc-Link Capacitor Of Solid State Power Supply In Parallel Operation
Abstract
In the medium frequency voltage source paralleled inverters, the paralleled diodes in IGBTs run as rectifier before the inverter starts, and the DC capacitor could be damaged by over voltage because of the transient of the circuit. This paper analyzed the characteristics of medium-frequency inverter in parallel operation, compared to the 50Hz inverter. The simplified system model is setup, and the impact of parallel inductor, the use age of DC voltage and filter capacitor on the safety of DC capacitor is analyzed theoretically. The Simulink model is established to verify the theoretical analysis. Finally, measures are proposed to protect DC capacitor.
Year
DOI
Venue
2012
10.1109/ISIE.2012.6237404
2012 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE)
Keywords
Field
DocType
medium-frequency inverter, parallel reverse rectifier, DC-Link capacitor safety
Inverter,Rectifier,Reservoir capacitor,Capacitor,Filter capacitor,Voltage source,Overvoltage,Control engineering,Electronic engineering,Decoupling capacitor,Engineering,Electrical engineering
Conference
Volume
Issue
ISSN
null
null
null
Citations 
PageRank 
References 
1
0.43
0
Authors
4
Name
Order
Citations
PageRank
Shixiong Nie110.43
ZiLing Nie221.21
Yanhao Wu310.43
Junjie Zhu465.29