Title | ||
---|---|---|
Designing and testing computer based screening engine for severe sepsis/septic shock. |
Abstract | ||
---|---|---|
This study addresses the role of a sepsis "sniffer", an automatic screening tool for the timely identification of patients with severe sepsis/septic shock, based electronic medical records. During the two months prospective implementation in a medical intensive care unit, 37 of 320 consecutive patients developed severe sepsis/septic shock. The sniffer demonstrated a sensitivity of 48% and specificity of 86%, and positive predictive value 32%. Further improvements are needed prior to the implementation of sepsis sniffer in clinical practice and research. |
Year | Venue | Field |
---|---|---|
2008 | AMIA | Septic shock,Intensive care medicine,Sepsis,Medicine |
DocType | ISSN | Citations |
Conference | 1942-597X | 1 |
PageRank | References | Authors |
0.41 | 0 | 4 |
Name | Order | Citations | PageRank |
---|---|---|---|
Vitaly Herasevich | 1 | 29 | 17.49 |
B Afessa | 2 | 1 | 0.41 |
Christopher G Chute | 3 | 2349 | 282.57 |
Ognjen Gajic | 4 | 3 | 5.56 |