Title
Modeling and diagnostic of incipient inter-turn faults for a three phase permanent magnet synchronous motor
Abstract
Insulation aging remains the leading cause of inter-turn fault in the stator winding of a PMSM. This aging weakens the insulation until its total deterioration. Types of the resulting faults differ according to the location of the weaknesses in the winding. During the last century, many fault diagnostic methods were developed. All these methods concern an existing permanent fault but not an intermittent one. The combination of end windings aging with electromagnetic efforts gives rise to intermittent inter-turns short circuit at the end windings. This paper contains a model of the intermittent short circuit and suggests an adapted online detection method based on the simulation and experimental results.
Year
DOI
Venue
2014
10.1109/IAS.2014.6978414
IAS Annual Meeting
Keywords
DocType
Citations 
ageing,circuit reliability,fault location,machine insulation,permanent magnet motors,short-circuit currents,stators,synchronous motors,pmsm stator winding,incipient interturn fault diagnostic method,insulation aging,intermittent interturn short circuit,online detection method,three phase permanent magnet synchronous motor model,weaknesses location,end windings vibration,fault detection,fault diagnosis,incipient fault,inter-turns fault,intermittent fault
Conference
2
PageRank 
References 
Authors
0.44
4
3
Name
Order
Citations
PageRank
Obeid, N.H.120.44
Boileau, T.260.91
Babak Nahid-Mobarakeh310223.04