Title
A simulation study evaluating the performance of high-density electrode arrays on myocardial tissue.
Abstract
Multielectrode arrays used to detect cellular activation have become so dense (electrodes per square millimeter) as to jeopardize the basic assumptions of activation mapping; namely, that electrodes are points adequately separated as to not interfere with the tissue or each other. This paper directly tests these assumptions for high-density electrode arrays. Using a finite element model with modified Fitzhugh-Nagumo kinetics, we represent electrodes as isopotential surfaces of varying widths and spacing ratio (SR) (center-to-center spacing divided by electrode width). We examine the signal strength and ability of a single electrode to detect activation due to a passing wavefront. We find that high-density arrays do not cause significant wavefront curvature or alter activation timing in the underlying tissue. Relationships between signal strength, cross talk, and array design are explained by the interaction of the propagating wavefront and induced sources on the isopotential electrodes. Sensitivity analysis shows that these results may be generalized to a wide range of physiologically relevant designs and applications. We conclude that electrode array designs in which electrode spacing greatly exceeds electrode diameter are overly conservative and that arrays with a SR of less than 2.0 may perform successfully in electrophysiological studies.
Year
DOI
Venue
2000
10.1109/10.846683
IEEE transactions on bio-medical engineering
Keywords
Field
DocType
high-density arrays,cellular biophysics,cardiology,bioelectric potentials,arrays,biomedical electrodes,modified fitzhugh-nagumo kinetics,electrode-tissue interface,high-density electrode arrays performance evaluation,electrode width,signal strength,physiological models,cellular activation detection,center-to-center spacing,finite element analysis,simulation study,cardiac mapping,activation detection,microelectrodes,muscle,propagation model,passing wavefront,myocardial tissue
Signal processing,Wavefront,Electrode array,Computer science,Square Millimeter,Electric potential,Finite element method,Electronic engineering,Electrode,Microelectrode
Journal
Volume
Issue
ISSN
47
7
0018-9294
Citations 
PageRank 
References 
2
1.64
0
Authors
2
Name
Order
Citations
PageRank
J. c. Eason121.64
R. a. Malkin221.64