Abstract | ||
---|---|---|
The paper focuses on experimental investigation for stator faults detection and fault detection methods of electrical drive systems using voltage source inverter (VSI) fed cage rotor induction machines (CRIM). Two experimental investigations (one stator phase unbalance and one stator phase open) have been performed to study the behaviour of the electrical machine. A description of the measurement system including acquisition and processing of the data is presented and stator current signature, current Park's vector and instantaneous power as diagnostic techniques are considered. |
Year | DOI | Venue |
---|---|---|
2007 | 10.1109/EFTA.2007.4416767 | Patras |
Keywords | Field | DocType |
asynchronous machines,data acquisition,drives,fault location,frequency convertors,rotors,stators,Park vector,cage rotor induction machine,data acquisition,electrical drive system,fault detection,frequency converter,instantaneous power,stator phase open,stator phase unbalance,voltage source inverter | System of measurement,Fault detection and isolation,Control theory,Data acquisition,Control engineering,Electronic engineering,Converters,Rotor (electric),Voltage source inverter,Stator,Engineering,Power (physics) | Conference |
ISSN | ISBN | Citations |
1946-0740 | 978-1-4244-0826-9 | 0 |
PageRank | References | Authors |
0.34 | 0 | 4 |
Name | Order | Citations | PageRank |
---|---|---|---|
Mihet-Popa, L. | 1 | 0 | 0.68 |
Octavian Prostean | 2 | 29 | 21.20 |
Ioan Filip | 3 | 25 | 18.11 |
Iosif Szeidert | 4 | 17 | 13.63 |