Title
Detection of the impedance variation for nuclear control cable using time frequency domain reflectometry
Abstract
In this paper, an impedance change localization for the nuclear control cable using the time-frequency domain reflectometry (TFDR) is proposed. The reference signal is designed by analyzing characteristics of the target cable and capacitive coupler. To be prepared for on-voltage experiment, the reference signal is injected into the target cable via capacitive coupler. The experiment using the TFDR and TDR is carried out to localize the impedance variation spot (0, 30, 50, 70, 90 Ω) in the target cable. Through the experiment, the accuracy of the proposed TFDR system is proved.
Year
DOI
Venue
2013
10.1109/I2MTC.2013.6555400
Instrumentation and Measurement Technology Conference
Keywords
Field
DocType
electric connectors,nuclear power stations,power cables,signal processing,time-domain reflectometry,time-frequency analysis,tfdr system,capacitive coupler,impedance change localization,impedance variation detection,impedance variation spot,nuclear control cable,on-voltage experiment,reference signal,target cable,time frequency domain reflectometry,time domain reflectometry,bandwidth,impedance,correlation,time frequency analysis
Signal processing,Signal reflection,Capacitive sensing,Electronic engineering,Electrical impedance,Time–frequency analysis,Reflectometry,Time-domain reflectometry,Impedance variation,Mathematics
Conference
ISSN
ISBN
Citations 
1091-5281
978-1-4673-4621-4
0
PageRank 
References 
Authors
0.34
2
4
Name
Order
Citations
PageRank
Seung-Jin Chang142.51
Chun Ku Lee261.57
Sin-Ho Lee331.23
Jin Bae Park41351102.77