Title | ||
---|---|---|
Stator Fault Diagnostics in Squirrel Cage Three-Phase Induction Motor Drives Using the Instantaneous Active and Reactive Power Signature Analyses |
Abstract | ||
---|---|---|
In this paper, the instantaneous active and reactive power signature analyses are presented for stator fault diagnosis in operating squirrel cage three-phase induction motors either directly connected to the mains or fed from inverters. Both simulation and experimental results are presented to show the effectiveness and the merits of the proposed approach that offers the possibility to detect this type of fault and to discriminate it from other abnormality conditions responsible for the same motor behavior by comparing the signature analyses of the two considered quantities. |
Year | DOI | Venue |
---|---|---|
2014 | 10.1109/TII.2014.2307013 | Industrial Informatics, IEEE Transactions |
Keywords | Field | DocType |
induction motor drives,invertors,reactive power,squirrel cage motors,stators,inverters,reactive power signature analyses,squirrel cage three-phase induction motor drives,stator fault diagnostics,Fault diagnosis,instantaneous active power (IAP),instantaneous reactive power (IRP),inter-turn short-circuit faults,open-circuit faults,signature analysis,squirrel cage induction motor drives,stator faults,voltage supply unbalance | Induction motor,Squirrel-cage rotor,Motor behavior,Computer science,Control theory,Control engineering,AC power,Stator | Journal |
Volume | Issue | ISSN |
10 | 2 | 1551-3203 |
Citations | PageRank | References |
11 | 0.71 | 20 |
Authors | ||
2 |
Name | Order | Citations | PageRank |
---|---|---|---|
M'hamed Drif | 1 | 33 | 3.53 |
António J. Marques Cardoso | 2 | 11 | 1.05 |