Title
Calibration of AC clamp meters
Abstract
This paper presents a non-invasive method for calibrating AC clamp meters for power and energy measurements. A procedure for determining the ratio error and the phase displacement in a wider frequency range up to 10 kHz is also analyzed. The results of measurements of both types of error for two clamp meters are presented at the end of the paper.
Year
DOI
Venue
2015
10.1109/I2MTC.2015.7151481
Instrumentation and Measurement Technology Conference
Keywords
DocType
Volume
calibration,clamps,power measurement,power meters,AC clamp meter calibration,energy measurement,noninvasive method,phase displacement,power measurement,clamp meter,lock-in amplifier,phase displacement,ratio error
Conference
65
Issue
Citations 
PageRank 
5
0
0.34
References 
Authors
3
2
Name
Order
Citations
PageRank
Karel Draxler1113.88
Renata Styblikova2113.88