Title
Optimizing Flip Angles for Metabolic Rate Estimation in Hyperpolarized Carbon-13 MRI.
Abstract
Hyperpolarized carbon-13 magnetic resonance imaging has enabled the real-time observation of perfusion and metabolism in vivo. These experiments typically aim to distinguish between healthy and diseased tissues based on the rate at which they metabolize an injected substrate. However, existing approaches to optimizing flip angle sequences for these experiments have focused on indirect metrics of t...
Year
DOI
Venue
2016
10.1109/TMI.2016.2574240
IEEE Transactions on Medical Imaging
Keywords
Field
DocType
Mathematical model,Magnetization,Maximum likelihood estimation,Magnetic resonance imaging,Biochemistry,Data models,Trajectory
Mathematical optimization,Search engine,Flip,Biological system,Computer simulation,Simulation,Flip angle,Hyperpolarized carbon-13 MRI,Ground truth,Fisher information,Imagination,Mathematics
Journal
Volume
Issue
ISSN
35
11
0278-0062
Citations 
PageRank 
References 
2
0.40
1
Authors
4
Name
Order
Citations
PageRank
John Maidens1384.99
Jeremy W. Gordon221.07
murat arcak31855195.31
Peder E. Z. Larson453.86