Abstract | ||
---|---|---|
The maintenance of control and instrumentation (C&I) cables is crucial to safety of operating nuclear power plants. Therefore, when an accident occurs, there is a need for an accurate assessment of the impact on the cable's integrity. Unfortunately, most cable diagnostic methods are destructive and real-time assessment of the effect of accidents is not possible. Thus, in this paper, we present an ... |
Year | DOI | Venue |
---|---|---|
2017 | 10.1109/TIM.2017.2664578 | IEEE Transactions on Instrumentation and Measurement |
Keywords | Field | DocType |
Power cables,Dispersion,Monitoring,Condition monitoring,Accidents,Propagation constant,Real-time systems | Noise reduction,Singular value decomposition,Electronic engineering,Loss-of-coolant accident,Condition monitoring,Reflectometry,Propagation constant,Distortion,Mathematics,Instrumentation | Journal |
Volume | Issue | ISSN |
66 | 7 | 0018-9456 |
Citations | PageRank | References |
1 | 0.37 | 9 |
Authors | ||
7 |
Name | Order | Citations | PageRank |
---|---|---|---|
Chun-Kwon Lee | 1 | 4 | 2.18 |
Gu-Young Kwon | 2 | 2 | 1.40 |
Seung-Jin Chang | 3 | 4 | 2.51 |
Moon Kang Jung | 4 | 3 | 0.79 |
Jin Bae Park | 5 | 1351 | 102.77 |
Han Sol Kim | 6 | 16 | 1.51 |
Yong-June Shin | 7 | 81 | 15.29 |