Abstract | ||
---|---|---|
An analog-to-digital converter (ADC) for monitoring the voltages of a stack of eight Li-ion batteries is presented. The converted voltage range for each battery is 3-4.2 V with a maximum nominal input voltage of 33.6 V. High-voltage (HV) switches and a single HV capacitor make up the HV track and hold. The remaining part of the circuit operates at a nominal 5-V supply. An interleaved extended-rang... |
Year | DOI | Venue |
---|---|---|
2017 | 10.1109/TCSII.2016.2597358 | IEEE Transactions on Circuits and Systems II: Express Briefs |
Keywords | Field | DocType |
Batteries,Capacitors,Monitoring,Computer architecture,Clocks,Battery charge measurement,Voltage measurement | Capacitor,Stack (abstract data type),Voltage,Communication channel,Cmos process,Electronic engineering,Battery (electricity),Mathematics,Ion,Power consumption | Journal |
Volume | Issue | ISSN |
64 | 6 | 1549-7747 |
Citations | PageRank | References |
0 | 0.34 | 5 |
Authors | ||
4 |
Name | Order | Citations | PageRank |
---|---|---|---|
Dante Gabriel Muratore | 1 | 2 | 1.37 |
Edoardo Bonizzoni | 2 | 162 | 47.30 |
Simone Verri | 3 | 0 | 0.34 |
Franco Maloberti | 4 | 8 | 3.87 |