Title
Assessment of the equivalent dipole layer source model in the reconstruction of cardiac activation times on the basis of BSPMs produced by an anisotropic model of the heart.
Abstract
Promising results have been reported in noninvasive estimation of cardiac activation times (AT) using the equivalent dipole layer (EDL) source model in combination with the boundary element method (BEM). However, the assumption of equal anisotropy ratios in the heart that underlies the EDL model does not reflect reality. In the present study, we quantify the errors of the nonlinear AT imaging based on the EDL approximation. Nine different excitation patterns (sinus rhythm and eight ectopic beats) were simulated with the monodomain model. Based on the bidomain theory, the body surface potential maps (BSPMs) were calculated for a realistic finite element volume conductor with an anisotropic heart model. For the forward calculations, three cases of bidomain conductivity tensors in the heart were considered: isotropic, equal, and unequal anisotropy ratios in the intra- and extracellular spaces. In all inverse reconstructions, the EDL model with BEM was employed: AT were estimated by solving the nonlinear optimization problem with the initial guess provided by the fastest route algorithm. Expectedly, the case of unequal anisotropy ratios resulted in larger localization errors for almost all considered activation patterns. For the sinus rhythm, all sites of early activation were correctly estimated with an optimal regularization parameter being used. For the ectopic beats, all but one foci were correctly classified to have either endo- or epicardial origin with an average localization error of 20.4 mm for unequal anisotropy ratio. The obtained results confirm validation studies and suggest that cardiac anisotropy might be neglected in clinical applications of the considered EDL-based inverse procedure.
Year
DOI
Venue
2018
10.1007/s11517-017-1715-x
Med. Biol. Engineering and Computing
Keywords
Field
DocType
Equivalent dipole layer,Forward and inverse problems of ECG,Activation times imaging,Influence of anisotropy,Fastest route algorithm
Inverse,Isotropy,Nonlinear system,Anisotropy,Tensor,Monodomain model,Electronic engineering,Finite element method,Boundary element method,Mathematics
Journal
Volume
Issue
ISSN
56
6
1741-0444
Citations 
PageRank 
References 
1
0.36
5
Authors
4
Name
Order
Citations
PageRank
Arno M. Janssen140.83
Danila Potyagaylo286.95
Olaf Dössel326456.10
Thom F Oostendorp412423.44