DukeSim: A realistic, rapid, and scanner-specific simulation framework in computed tomography.
Abstract
The purpose of this study was to develop a CT simulation platform that is 1) compatible with voxel-based computational phantoms, 2) capable of modeling the geometry and physics of commercial CT scanners, and 3) computationally efficient. Such a simulation platform is designed to enable the virtual evaluation and optimization of CT protocols and parameters for achieving a targeted image quality while reducing radiation dose. Given a voxelized computational phantom and a parameter file describing the desired scanner and protocol, the developed platform DukeSim calculates projection images using a combination of ray-tracing and Monte Carlo techniques. DukeSim includes detailed models for the detector quantum efficiency, quantum and electronic noise, detector crosstalk, subsampling of the detector and focal spot areas, focal spot wobbling, and the bowtie filter. DukeSim was accelerated using GPU computing. The platform was validated using physical and computational versions of a phantom (Mercury phantom). Clinical and simulated CT scans of the phantom were acquired at multiple dose levels using a commercial CT scanner (Somatom Definition Flash; Siemens Healthcare). The real and simulated images were compared in terms of image contrast, noise magnitude, noise texture, and spatial resolution. The relative error between the clinical and simulated images was less than 1.4%, 0.5%, 2.6%, and 3%, for image contrast, noise magnitude, noise texture, and spatial resolution, respectively, demonstrating the high realism of DukeSim. The runtime, dependent on the imaging task and the hardware, was approximately 2-3 minutes per rotation in our study using a computer with 4 GPUs. DukeSim, when combined with realistic human phantoms, provides the necessary toolset with which to perform large-scale and realistic virtual clinical trials in a patient and scanner-specific manner.
Year
DOI
Venue
2019
10.1109/TMI.2018.2886530
IEEE transactions on medical imaging
Keywords
Field
DocType
Detectors,Computed tomography,Computational modeling,Phantoms,Imaging phantoms,Photonics
Computer vision,Monte Carlo method,Imaging phantom,Noise (electronics),Image quality,Scanner,Artificial intelligence,General-purpose computing on graphics processing units,Detector,Image resolution,Mathematics
Journal
Volume
Issue
ISSN
38
6
1558-254X
Citations 
PageRank 
References 
0
0.34
0
Authors
6
Name
Order
Citations
PageRank
Ehsan Abadi100.34
Brian P. Harrawood2173.00
Shobhit Sharma300.34
Anuj Kapadia400.34
William P Segars591.81
Ehsan Samei62814.00