Title
Comparative Evaluation Of Stress Distribution In Bone Surrounding Implant Using Different Implant Biomaterials: A 3dfea Study
Abstract
Advances in Finite Element Analysis has made tremendous progress in its application to study stress pattern in dentistry especially in implant prosthodontics. Titanium implant material prosthesis is used in most of the restoration or replacement of lost teeth over last three decades. Some of the prevailing titanium implant failures and limitations due to various reasons has resulted in alternative materials with more compatibility. In the present study, an attempt is made to compare stress distribution of zirconia implant material with titanium. Stress distribution and deformation in bone surrounding implant are compared by these two materials. Results obtained showed zirconia implant demonstrated similar stress patterns compared to titanium implant assembly and also agree well with the available literature.
Year
DOI
Venue
2019
10.3233/JCM-181057
JOURNAL OF COMPUTATIONAL METHODS IN SCIENCES AND ENGINEERING
Keywords
Field
DocType
FEM analysis, titanium implant, zirconia implant, stress distribution
Dentistry,Implant,Materials science
Journal
Volume
Issue
ISSN
19
2
1472-7978
Citations 
PageRank 
References 
0
0.34
0
Authors
6
Name
Order
Citations
PageRank
Syeda Amtul Haseeb100.34
Abdul Khader210.70
satish b shenoy302.03
Y. G. Naveen400.34
P. Giridhar Kamath500.34
K. C. Vinaya600.34