Title | ||
---|---|---|
Model-Based High-Definition Dynamic Contrast Enhanced MRI for Concurrent Estimation of Perfusion and Microvascular Permeability. |
Abstract | ||
---|---|---|
•The first work on high-definition whole-brain DCE MRI that simultaneously achieves high temporal resolution of 1.5 s and high spatial resolution of 1.0 mm3.•Precise definition of patient-specific arterial input function and tissue output function for accurate quantification of microvascular functions.•Concurrent estimation of perfusion and microvascular permeability in brain cancer.•Model-based DCE reconstruction from incomplete measurements without apparent loss of contrast dynamics.•Comparison between the proposed high-definition DCE MRI and conventional routine (vendor-provided state-of-the-art) DCE MRI. |
Year | DOI | Venue |
---|---|---|
2020 | 10.1016/j.media.2019.101566 | Medical Image Analysis |
Keywords | Field | DocType |
Magnetic resonance imaging,Dynamic contrast enhanced,High definition,Microvascular permeability,Brain cancer | Isotropy,Residual,Superposition principle,Finite set,Pattern recognition,Algorithm,Artificial intelligence,Sampling (statistics),Dynamic contrast-enhanced MRI,Image resolution,Mathematics,Perfusion | Journal |
Volume | ISSN | Citations |
59 | 1361-8415 | 1 |
PageRank | References | Authors |
0.36 | 0 | 6 |
Name | Order | Citations | PageRank |
---|---|---|---|
Joon Sik Park | 1 | 1 | 0.36 |
Eunji Lim | 2 | 1 | 0.36 |
Seung-Hong Choi | 3 | 1 | 0.70 |
Chul-Ho Sohn | 4 | 1 | 0.70 |
Joonyeol Lee | 5 | 1 | 1.03 |
Jaeseok Park | 6 | 19 | 6.05 |