Title
Rotation Axis Calibration of Laser Line Rotating-Scan System for 3D Reconstruction
Abstract
The laser line rotating-scan system has been a popular method for 3D reconstruction. But the rotating axis of the scanner usually does not coincide with the camera origin point, which makes this technique a bit more complex. This paper proposes a rotation axis calibration method to solve the problem for more accurate 3D imaging. The calibration parameters are defined as the external parameters (rotation and translation) between the camera coordinate system and the world coordinate system of the rotation axis. With the rotation axis calibration, 3D results of a single frame are transformed into the world coordinate system of the rotation axis. Finally, we realize multi-frame splicing only with the rotation angle provided by the scanner. Experiments on real data show our method is basically correct and practical.
Year
DOI
Venue
2020
10.1109/iCAST51195.2020.9319495
2020 11th International Conference on Awareness Science and Technology (iCAST)
Keywords
DocType
ISSN
Line structured light,3D reconstruction,laser triangulation,rotation axis calibration
Conference
2325-5986
ISBN
Citations 
PageRank 
978-1-7281-9120-1
0
0.34
References 
Authors
0
8
Name
Order
Citations
PageRank
Zhihao Zhu135.13
Jian Yang200.68
Xianglong Wang300.68
Guanqi Qi400.34
Chuang Wu500.34
Hao Fan603.04
Lin Qi7278.68
Junyu Dong839377.68