Title
Evaluating The Agreement And Reliability Of A Web-Based Facial Analysis Tool For Rhinoplasty
Abstract
Purpose Rhinoplasty is one of the most common and challenging plastic surgery procedures. Facial analysis is a crucial step in planning. Utilizing three-dimensional (3D) model of a patient's face is an emerging way of performing facial analysis. This paper evaluates the agreement and reliability of facial measurements taken using a web app, located at digitized-rhinoplasty.com, that utilizes 3D models of the patient's face. Methods Eleven measurements were calculated on 16 human subjects. Three methods of measurements were performed: direct measurements on human subjects' faces, measurements on 2D photographs, and measurements on 3D models of face scans. The Bland-Altman plot is used for testing the agreement between the web app and the well-known Blender 3D modeling software. Intra-rater and inter-rater reliability was calculated and compared for 2D and 3D methods using the intraclass correlation coefficient (ICC) method. The statistical analysis methods were checked for the normality and homoscedasticity assumptions. Results The results indicate that the web app and Blender software show agreement within 95% confidence limits. The web app performs well in intra-rater and inter-rater reliability statistical analysis. The web app's reliability scores are consistently better than facial analysis software which was found highly reliable in a previous study. We also compare the methods of measurements in terms of time, ease of use, and cost. Conclusion The utilization of 3D computer modeling for facial analysis has its advantages and started to become more common due to recent advances in technology. The web app utilizes 3D face scans for pre-operative planning and post-operative evaluation of facial surgeries. The web app performs well in agreement and inter-/intra-reliability analysis and performs consistently better than software that works utilizing 2D photographs. The web app provides accurate, repeatable, affordable, and fast facial measurements for facial analysis when compared to direct and 2D methods.
Year
DOI
Venue
2021
10.1007/s11548-021-02423-z
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY
Keywords
DocType
Volume
Surgery planning, Facial analysis, Rhinoplasty, Agreement, Reliability, Facial measurements, 3D model, Intraclass correlation coefficient, Bland-Altman
Journal
16
Issue
ISSN
Citations 
8
1861-6410
0
PageRank 
References 
Authors
0.34
0
6