Title
System Identifications, Validation and Overall Mathematical Modeling of Small Scale Wind Turbine
Abstract
In this paper, calculation of overall system parameters, identification through laboratory setup and its validation has been done. Moreover, comparative performance of sensor and sensorless control for Permanent Magnet Synchronous Generator (PMSG) with DC bus is presented. The system model contains a PMSG model, sensorless Extended Kalman Filter (EKF), three phase Voltage Source Converter (VSC) with fix DC bus system. Overall system modeling of PMSG and calculation from the scratch of the parameters such as, generator phase resistance (Rs), d-q axis inductance (Ld-Lq), rotor flux linkage (lambda r) etc. have been defined in this paper. However, Identified parameters are used in hardware prototype in order to validate and verify system performance. Generator measured speed, d-q axis currents are control by Field Oriented Control (FOC) in sensor-based system, and estimated parameters are used in sensorless control scheme. Hardware prototype is used for parameters identification and experiments, which comprises of, individual gear-less PMSG, ETH position sensor, LEM voltage and current sensors, and dSPACE microlab box.
Year
DOI
Venue
2021
10.1109/ISIE45552.2021.9576458
PROCEEDINGS OF 2021 IEEE 30TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE)
Keywords
DocType
ISSN
Wind Energy Conversion System (WECS), Permanent Magnet Synchronous Generator (PMSG), Extended Kalman Filter (EKF), System parameter's Identifications, Field Oriented Control (FOC), Voltage Source Converter (VSC), Sensorless Control
Conference
2163-5137
Citations 
PageRank 
References 
0
0.34
0
Authors
3
Name
Order
Citations
PageRank
Amin Qureshi100.34
Amin Hajizadeh286.62
Mohsen Soltani32811.77