Title | ||
---|---|---|
Grid Current Harmonic Suppression for Motor Drive with Reduced DC-Link Capacitance in Weak Grid |
Abstract | ||
---|---|---|
Motor drives with reduced DC-link capacitance may face grid current distortion or even instability under weak grid condition. In this paper, the small signal model of reduced DC-link capacitance drive system under weak grid condition is derived and analyzed. On this basis, an impedance reshaping method is proposed to suppress the harmonics of the grid-side current. By extracting DC-link harmonics near the LC resonant frequency and reconstructing the virtual admittance of the drive, the active damping voltage control signal is generated to suppress the harmonic of the grid-side current at the specific frequency. The THD of the grid-side current was reduced from 53% to 39%. The experiment was carried out on a 5.5kW permanent magnet motor drive platform with reduced DC-link capacitance, and the effectiveness of the control strategy was verified by experiments. |
Year | DOI | Venue |
---|---|---|
2021 | 10.1109/IECON48115.2021.9589448 | IECON 2021 - 47TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY |
Keywords | DocType | ISSN |
reduced DC-link capacitance, weak grid, grid-side current harmonic suppression, impedance reshaping | Conference | 1553-572X |
Citations | PageRank | References |
0 | 0.34 | 0 |
Authors | ||
6 |
Name | Order | Citations | PageRank |
---|---|---|---|
Zekun Ren | 1 | 0 | 0.34 |
Gaolin Wang | 2 | 104 | 16.33 |
Dawei Ding | 3 | 0 | 0.34 |
Guoqiang Zhang | 4 | 0 | 1.01 |
Nannan Zhao | 5 | 0 | 0.68 |
DianGuo Xu | 6 | 22 | 30.76 |