Title
Optimal Regional Voltage Thresholds for Identifying Ablation Targets in Patients with Atrial Fibrillation
Abstract
Pulmonary vein isolation plus ablation of additional arrhythmic substrate is used to treat persistent atrial fibrillation (AF) patients. Atrial arrhythmogenic substrate contains increased myocardial fibrosis and displays low bipolar voltage < 0.5 mV during SR or < 0.3-0.5 mV during AF. However, discrepancies were reported in the extent and location oflow voltage areas (LVA) between SR and AF...
Year
DOI
Venue
2021
10.23919/CinC53138.2021.9662839
2021 Computing in Cardiology (CinC)
Keywords
DocType
Volume
Geometry,Low voltage,Correlation,Veins,Atrial fibrillation,Lung,High-voltage techniques
Conference
48
ISBN
Citations 
PageRank 
978-1-6654-7916-5
0
0.34
References 
Authors
0
8
Name
Order
Citations
PageRank
Deborah Nairn100.34
Claudia Nagel201.01
Björn Müller-Edenborn300.34
Heiko Lehrmann400.34
Thomas Arentz500.34
Olaf Dössel626456.10
Amir Jadidi700.34
Axel Loewe811.03